6) Cover the pressure washer and store it in a
clean, well ventilated and dry place. Ensure
storage area is at room temperature.
*** See in-store to purchase fuel stabilizer or
pressure washer antifreeze.
If you wish to drain the fuel instead of adding
fuel stabilizer, please follow these steps:
1) Turn fuel shut-off valve to the “OFF” position.
Remove drain hex bolt (A) from the carburettor
(B).
2) Now turn fuel shut-off valve to the “ON” position
and drain the fuel from the tank, carburettor and
hose.
3) Replace the carburetor drain
hex bolt once
the fuel is completely drained.
PREVENTING FREEZING DAMAGE:
If your pressure washer is subjected to
freezing temperatures, damage could occur.
This type of damage is not covered under
warranty. To avoid possible damage, a small
amount of antifreeze can be used.
Place the unit on its side with the water inlet
facing upwards. Pour 1/4 cup of antifreeze
into the water inlet.
Disconnect spark plug wire, and then pull
recoil starter several times to circulate the
antifreeze in the pump system. Reconnect
spark plug wire.
It is also important to make sure the wand and
all hoses are disconnected and drained of all
water or th
ey may burst.
When taking pressure washer out of storage,
run water through the system until it runs
clear.